  • The only truly modular diagnostic station that grows with your needs
  • Easily captures automated blood pressure measurements at the touch of a button.
  • The non-invasive blood pressure base unit module uses the oscillometric method, with both pulse rate and the mean arterial blood pressure (MAP) displayed in about 30 seconds
  • Adult Plus and Large Adult Plus cuffs come standard
€398.75
SKU
9006M
Continue Shopping

Additional Information -

  • Clinical-grade Advantage BP technology from SunTech Medical
  • Contemporary, compact design with an integrated handle and easy-to-read display
  • Manual blood pressure mode for real-time verification
  • Customizable average mode options
  • Next-generation EMR ready with HL7 messaging for electronic data transfer
  • Network enabled with built-in Ethernet or optional Wi-Fi
  • Lithium-ion power for longer-lasting battery life and a lighter weight
  • Built-in memory with up to 99 charting sessions
  • New Pediatric Mode to ensure accurate measurements for younger patients
  • Firmware upgradeable

Technical Specifications

SpO2

Saturation Normal (no motion):

70-100%Arms ± 2%

Saturation Motion:

N/A

Low Perfusion:

N/A

Pulse Heart rate:

20-300 BPM: ±3 BPM

Pulse Heart rate w/motion:

20-300 BPM: ±3 BPM

Temperature

Temperature  Accuracy:

Quick Mode (Oral): ± 0.3°C

Temperature Accuracy:

Std. Mode (Aux/Rectal): ± 0.1°C

Temperature Accuracy:

Direct Mode ± 0.1°C

Response Time:

4 sec (quick mode); 10-15 sec. (Axillary/Rectal); 60 sec.(direct mode)

Resolution:

0.1°C

Blood Pressure

Range:

Pressure: Diastolic: 20-200 mmHg (adult), 20-160 mmHg (pediatric).

Systolic: 40-260 mmHg (adult), 40-230 mmHg (pediatric)

Heart Rate: 30-220 BPM (beats per minute)

Accuracy (BP):

Meets or exceeds ANSI/AAMI/ISO 81060-2:2013 standard for non-invasive accuracy (±5mmHg mean error with 8mmHg standard deviation).

General Specifications

Conditions for Use:

Operating: 10°C (50°F) to 40°C (104°F) 15 – 90% RH non-condensing - 700 kPa - 1060 kPa.

Operating the monitor in an environment at maximum temperature can produce temperatures exceeding 41°C (41.6°C highest recorded) on a patient-applied part.

It is up to the operator to determine if this temperature is too high based upon the condition of the patient and, if so, to ensure the ambient temperature of the environment is 38°C or below.

Storage:

-20°C (-4°F) to 55°C (149°F) 15 – 90% RH non-condensing - 500 kPa - 1060 kPa. Performance can be affected if used or stored outside the specified temperature, humidity, or altitude listed in the ranges above.

Power:

Internal power supply. Input: 100-240 VAC @ 1.5A max, 50-60 Hz. Output +9VDC @ 5A IEC 320 type input connector.

Battery:

Type: 7.2v, 6600mAh Internal Lithium-Ion battery Run Time (full charge): ~20 hrs* / 200 BP cycles Charge Time: ~6 hrs @ 23deg Celsius +/- 2deg 

*Unit with BP, Temp, SpO2, Wi-Fi, barcode scanner

Calibration:

The accuracy of cuff -pressure transducers/indicators should be verified bi-annually.

Safety Systems:

Independent hardware over-pressure circuit and redundant software overpressure algorithm to limit cuff pressure to less than 300 mmHg (+20/-10mmHg). Independent hardware timing circuit and redundant software timer algorithm to limit the duration of a blood pressure cycle to less than 180 seconds.

Dimensions:

Size (without thermometer option): 8” H x 6.75’’ W x 5.2’’ D or 215mm H x 190mm W x 140mm D

Standards:

ANSI/AAMI ES60601-1:2005/(R)2012 and A1:2012, C1:2009/(R)2012 and A2:2010/(R)2012, EN 60601-1:2006/A1:2013, IEC 60601-1-2: 2007 EMC, IEC 80601-2-30: 2013, ISO 80601-2-61: 2011, ISO 15223-1:2012, ISO 10993-1, 2009, ISO 10993-5, 2009, EN ISO 10993-10, 2010, ISO 81060-2:2013, EN 50419: 2006, EN ISO 14971:2009, CSA C22.2 No. 60601-1, EN ISO 81060-1: 2012, IEC 60601-1-6: 2013

Classifications:

Equipment Classification: Class IIa per MDD, Class I (Electrical Shock), Continuous mode of operation, CE

Ingress of liquid:

Ingress Protection: IPX1: This device is protected against harmful effects of dripping water per IEC 60529.

Limited Warranty

Main unit (SpO2 modules, Temp modules):

3 years

Blood Pressure Cuffs:

2 years

Battery:

1 year

 

ADView Accessories

 

SpO2 ChipOx Finger Sensor, Adult

SpO2 ChipOx Finger Sensor, Pediatric

Thermometer Probe Covers (20/Box, 25 Boxes/Case)  

Thermometer Probe Covers (5000/Case) 

Oral/Axillary Temperature Probe

Oral/Axillary Temperature Well 

Oral/Axillary Temperature Kit (Probe, Well, Probe Covers)

Rectal Temperature Probe.

Rectal Temperature Well

Rectal Thermometer Kit (Probe, Well, Probe Covers)

Rechargeable Lithium-Ion Battery

Power Cord, U.K., 240VAC 

USB Wi-Fi Dongle

Printer with Paper

Barcode Scanner

9005SP

9005SPDYS

9000TP

9000TP-5000

9000TOP

9005TWB

9005TOK

9000TRP

9005TWR

9005TRK

9005BAT

9000PCUK

9005DON

9005P

9005SCAN